AC COACHES SYSTEM

AC COACHES

Types of AC coaches
  • Self generated- Conventional & RMPU type
  • EOG - Conventional & RMPU type
SG (Self generating)
Power supply for AC equipments is met from axle driven transom mounted brushless alternator rated 110v DC supply.
Equipments:
  • 2 X 18 kw alternator running at > MFO
  • 800 Ah cells,
  • 200A cap battery charger,
  • 415 v, 50 Hz, 3 phase pre-cooling plug- 2 nos,
  • RRU- 18 kw at 130V
EOG (End-on – generation)
Power supply is derived from DG set 415 V/ 750v, 3 phase, 50 Hz. Power is distributed to entire rake through 2 sets of 3 phase, 415/ 750 v feeders. Each coach is provided with control, distribution and feeder arrangement on control panel. The AC equipments works on 415 v supply and lighting equipment on 110 v AC obtained from 3 KVA, 415 / 190 V, 4 wire step down transformer.
Drawback of conventional type AC coaches:
It has open type of compressor system, so…
  • More spacious, heavy weight, more maintenance cost.
  • More leakage problem from pipes and joints.
  • More man power required.
  • Consuming more, less energy efficient.
Features of RMPU type AC coaches:
  • Light in weight.
  • low cost of installation
  • no water leakage
  • Hermetically sealed compressor, so no out side fittings.
  • Use of 3 phase induction motor, less maintenance cost.
  • No chance of damage by CRO and flash flood etc.
  • More energy efficient, modern technology and excellent performance.
Comparison of RMPU with conventional AC coach
SNDescriptionRoof mountedConventional
1weight900 kg2700 kg
2Installation time4 hrs4 days *
3RefrigerantF-22 (CHCl F 2)F-12 (CCl 2 F 2)
4Refrigeration charge< 3 kg15 – 20 kg
5System designHermitically sealedOpen
6Refrigerant leak potentialNilEnormous
7MaintenancelittleHeavy
8Dust collectionlittleHeavy
9Damage due to CRONILHeavy
10Damage due to flash floodNILHeavy
11PerformanceExcellentDeteriorates quickly due to dust collection.
12TechnologylatestOld and absolute.
13Water drop on passengerNILsometimes
14Fresh airTaken from roofTaken from side wall of toilet
15Capacity control25% to 100% (4 compressors)50% to 100% (2 compressors)
16Down time for repair4 hrs (for replacement of RMPU)4 days (depends upon the equipment failed)
17Motor used3 phase I.M.DC motor
18Tones7.0 x 25.2 X 2
19Energy consumptionlessMore
20Humidity controlBy microprocessor based controlling systemOld conventional method